Principle
Magnetic Level Gauge employ two
elementary principles.
- Archimedes Principle according to
which a body immersed in a liquid
receives buoyancy equal to the weight of
displaced liquid.
- Principle of attraction among
dissimilar poles of permanent magnets
and that of repulsion between like
poles.
A float-containing magnet follows liquid
level in the liquid chamber, which
corresponds, to the level in the
tank.Position of the float inside the
chamber is indicated outside by bicoloured
flapper embedded with magnet by 180°
rotation and setting
|
|
Specificaitons
- CC or Level Range:
- Upto 3 meter in single piece.
- (Others on request)
- Material for wetted parts:
- Stainless steel as standard
- (Others on request).
- Float :
- Stainless steel, Titanium, PTFE
- (Others on need basis to meet
process conditions)
- Flange rating: 150lbs to 2500lbs
- Scale: Stainless Steel or Acrylic
- Operating Temperature: Upto 200° C
- Operating Pressure: up to 200bar
- Specific Gravities: 0.4 and above
- Options: Magnetic alarm switches for
low / high level or signaling the level
at one or more points.
|